Greasing Procedure
Following is the standard procedure for greasing ball bearings:



  1. Wipe grease from the pressure fitting, clean dirt, debris and paint around the grease relief plug. This prevents foreign objects from entering the grease cavity.

  2. Remove the grease relief plug and insert a brush into the grease relief as possible. This will remove any hardened grease. Remove the brush and wipe off any grease.

  3. Add grease per Table 2.

  4. Allow the motor to operate for approximately 30 to 40 minutes before replacing the grease relief plug. This reduces the chance that bearing housing pressure will develop.

How Often Should Bearings Be Greased?
Bearings should be lubricated at an average frequency as found in Table 3. Operational environment and type of grease may require more frequent lubrication.


Conclusion
It is recommended that the type of grease used on each motor is recorded in order to avoid premature bearing failure. In many cases, you may be able to standardize the type of grease used in a majority of your motors. It is also good practice to let your motor repair center know the type of grease in case the standard grease used by the repair center conflicts with your standard grease.
Is this article helpful? Please help us to click our sponsors.

No comments:

Search here:

Translate to :

Official Website

Name:*
Email:*
Tel / HP:
Subject:*
Message:*
Verification No.:*
contact form faq

Our Services :

- Machine troubleshooting
- Automation, mechanical, instrumentation, electrical design, installation & commisioning
- Machine design, machine installation/relocation
- PLC software, programming, installation & commisioning
- Instruction manual, troubleshooting guide, technical guide etc
- Panel maker (distribution, control desk, capacitor bank, PLC, starter unit, inverter unit etc)
- Inverter design, installation & commisioning
- Motor
- Energy saving solutions
- Etc